Skip to content
Warehouse Operating Hours: Monday - Friday: 1:00 PM - 08:30 PM - VISIT OUR STORE

7835-34-1003 | Genuine Komatsu® Panel Monitor Cluster Gauge

NO CORE CHARGE
Free shipping on purchases over $100,
Order within the next Dec 17 for delivery by Dec 20.
  • Product SKU: 7835-34-1003
  • Availability: In Stock
Original price $1,359.00 - Original price $1,359.00
Original price
$1,359.00
$1,359.00 - $1,359.00
Current price $1,359.00
Hurry! only 1 left in stock!

Pickup available at 111 Belton Drive Unit -B Usually ready in 24 hours

Buy safely, Easy Returns within 30 days.
365 Days warranty
Orders placed before 7-PM EST will ship same business day
Ask about this product
Your message has been successfully sent to the store owner!

Description: Panel Monitor Cluster Gauge
Condition: New 
Brand: Komatsu® 
Part Number: 7835-34-1003, 7835341003

Fitment Guide 7835-34-1003:
For Komatsu Excavator
PC200-8M0 PC200LC-8M0 PC220-8M0 PC220LC-8M0 
PC300-8M0 PC300LC-8M0 PC350-8M0 PC350LC-8M0

A monitor/display panel 7835-34-1003, also called an operator monitor or main monitor, is an electronic control and information display unit found in construction equipment — such as excavators, bulldozers, and wheel loaders — that shows the machine’s operating data, warnings, and system status to the operator.

 
  1. Display machine status

    • Shows engine speed (RPM), hydraulic pressure, fuel level, temperature, and other key parameters.

    • Displays operating hours (hour meter).

  2. Warning & diagnostic alerts

    • Provides visual (and sometimes audible) alarms if there’s a problem — such as low oil pressure, overheating, or hydraulic fault.

    • Often includes fault codes to help technicians troubleshoot.

  3. System control & settings

    • Lets the operator adjust settings like work modes, idle speed, attachment configuration, and language preferences.

    • May include touchscreen input or physical buttons.

  4. Communication with ECUs

    • Connects to the machine’s electronic control units (ECUs) via CAN bus or similar communication protocols.

    • Transmits data both ways (monitor shows info, and operator inputs commands).

  5. Data logging

    • Stores event history and fault logs for maintenance and service technicians.


Signs of Faulty 7835-34-1003

 

1. Blank or Dead Screen

  • The display doesn’t turn on at all when the ignition is on.

  • No backlight, no icons, and no response from buttons.
    Possible causes:

    • Power supply issue (blown fuse, bad wiring, or loose connector)

    • Internal circuit board damage

    • Faulty monitor unit itself

2. Dim, Flickering, or Faded Display

  • Screen is very faint or the backlight flickers.

  • Hard to read under sunlight.
    Possible causes:

    • Failing backlight or LCD panel

    • Voltage fluctuation or grounding problem

    • Moisture or heat damage

3. Display Freezes or Lags

  • The screen freezes on one image.

  • Takes a long time to load menus or switch screens.
    Possible causes:

    • Software or firmware corruption

    • Communication errors with the machine’s ECU

    • Internal memory fault

4. Missing or Incorrect Data

  • Fuel level, engine hours, or hydraulic readings show “—” or wrong numbers.

  • Some menu items disappear or can’t be accessed.
    Possible causes:

    • Faulty data connection (CAN bus issue)

    • Internal processing fault

    • Corrupted configuration data

5. No Warning Lights or False Alarms

  • Machine runs but no warning indicators appear (even when faults exist).

  • Or, random false alarms appear on the screen.
    Possible causes:

    • Logic board malfunction

    • Software communication error

    • Corrosion or short circuit inside the monitor

6. Buttons or Touch Inputs Not Responding

  • Hard keys don’t work or only some respond.

  • Touchscreen (if equipped) is inaccurate or dead.
    Possible causes:

    • Worn button contacts or touch sensors

    • Water/dust ingress

    • Damaged input controller

7. Intermittent Operation

  • Works sometimes, goes blank randomly when hitting bumps or vibrations.
    Possible causes:

    • Loose wiring harness connection

    • Cracked solder joints on the circuit board

    • Failing power regulator inside the monitor

8. Burning Smell or Overheating

  • Unit feels unusually hot or emits electrical smell.
    Possible cause:

    • Short circuit or component burnout inside the monitor


Komatsu® is a well-known Japanese company founded in 1921 that specializes in the production of heavy machinery, including fuel injection pumps. Its products are characterized by high reliability, advanced technologies and efficiency, which makes them popular in various industries. Komatsu® actively innovates, focusing on reducing the environmental impact of its products. Thanks to its experience and high quality standards, the company occupies a leading position in the world market.